Mitsubishi Electric CV air cooled chillers
In terms of placement, a distinction is made between outdoor and indoor (also known as ducted) chillers. Outdoor chillers are usually fitted with axial fans, while their indoor counterparts are made with higher pressure (eg centrifugal) fans. The latter are usually used in case of lack of outdoor space.
According to the principle of operation, we distinguish between standard and free-cooling chillers. Free cooling chillers are used in areas of technology that require cooling 24 hours a day, 365 days a year. These applications can be used to cool the liquid with the help of outdoor air temperature during the winter and during the transitional seasons (spring, autumn). Generally 80-90% of the power consumption of any air conditioner is provided by the compressor. When the chillers is cooling with outdoor air, the compressor can be switched off, resulting in very significant energy savings during these periods.
Refigirant gas | ODP | GWP |
HFC R-410A | 0 | 2088 |
HFC R-134A | 0 | 1430 |
HF0 R1234ze | 0 | 6 |
HFC R-513A | 0 | 631 |
HFC R-407C | 0 | 1774 |
R-454B | 0 | 466 |
R32 | 0 | 677 |
The GWP shows the amount of CO2 equivalent to the test substance in the greenhouse effect over 100 years (kgCO2 / kg). The lower the number, the less potent the greenhouse effect.
Ozone depletion is indicated by the ODP value (Ozone Depletion Potential), which can be between 0 and 1.
Air cooled chillers | ||||||
Type | Capacity | Function | Refrigerant gas | Compressor | Fan | Heat exchanger |
i-BX 004M – 035T | 4,30 – 35,10 kW | Cooling | HFC R-410A | Inverter driven scroll | Axial | Plate |
i-NX 0151P – 0502P | 43,88-129,3 kW | Cooling | HFC R-410A | Inverter driven scroll | Axial | Plate |
i-NX2-G07 0051 – 0112 | 50,1 – 220 kW | Cooling | R32 | Inverter driven scroll | EC Axial | Plate |
NX 0614P – 1214P | 160,0-327 kW | Cooling | HFC R-410A | Scroll | Axial | Plate |
NX-G06 0614P-1214P | 153 – 314 kW | Cooling | R454B | Scroll | Axial | Plate |
NX 0614T – 1214T | 160,0 – 327,0 kW | Cooling | HFC R-410A | Scroll | Axial | Shell and tube |
NX-G06 0614T-1214T | 153 – 314 kW | Cooling | R454B | Scroll | Axial | Shell and tube |
FX 0751 – 1801 | 140 – 396 kW | Cooling | HFC R-134a | Screw | Axial | Shell and tube |
FX-G05 0751 – 1801 | 140 – 396 kW | Cooling | HFC R513A | Screw | Axial | Shell and tube |
TECS2 HFO 0351 – 1053 | 339 – 1017 kW | Cooling | HF0 R1234ze | Oil-free centrifugal | EC Axial | Flooded |
TECS2-G05 0211 – 1154 | 218 kW – 1789 kW | Cooling | HFC R-513A | Oil-free centrifugal | Axial | Flooded |
TECS2 0211 – 1154 | 220 – 1324 kW | Cooling | HFC R-134a | Oil-free centrifugal | Axial | Flooded |
i-FX-G04 2202 – 7823 | 477 – 1697 kW | Cooling | HF0 R1234ze | Inverter driven screw | EC Axial | Shell and tube |
i-FX-G01 2202 – 7223 | 383 – 1463 kW | Cooling | HFC R-134a | Inverter driven screw | Axial | Shell and tube |
i-FX-G05 2202 – 7223 | 479 – 1679 kW | Cooling | HFC R-513A | Inverter driven screw | Axial | Shell and tube |
NECS-Y 0202T – 0612T | 55 – 130 kW | Cooling | HFC R-410A | Scroll | Axial | Shell and tube |
NX2-G06 0042 – 0222 | 40,1 – 212 kW | Cooling | R454B | Scroll | Axial | Plate |
NX2-G02 0042 – 0222 | 42,5 – 226 kW | Cooling | HFC R-410A | Scroll | Axial | Plate |
NX2-G06 0184P – 0374P | 167 – 346 kW | Cooling | R454B | Scroll | Axial | Plate |
NX2-G06 0184T – 0374T | 167 – 346 kW | Cooling | R454B | Scroll | Axial | Shell and tube |
NX2-G02 0184P – 0374P | 176 – 367 kW | Cooling | HFC R-410A | Scroll | Axial | Plate |
NX2-G02 0184T – 0374T | 176 – 367 kW | Cooling | HFC R-410A | Scroll | Axial | Shell and tube |
NX2-G06 0404 – 0928 | 379 – 872 kW | Cooling | R454B | Scroll | Axial | Shell and tube |
NX2-G02 0404 – 0928 | 398 – 922 kW | Cooling | HFC R-410A | Scroll | Axial | Shell and tube |
FX2-G04 0252 – 1593 | 252 – 1572 kW | Cooling | HF0 R1234ze | Screw | Axial | Shell and tube |
FX2-G01 0322 – 1883 | 310 – 1839 kW | Cooling | HFC R-134a | Screw | Axial | Shell and tube |
FX2-G05 0322 – 1883 | 310 – 1839 kW | Cooling | HFC R-513A | Screw | Axial | Shell and tube |
Ducted chillers | ||||||
Type | Capacity | Function | Refrigerant gas | Compressor | Fan | Heat exchanger |
NX-C 0072 – 1204 | 17,4 – 291 kW | Cooling | HFC R-410A | Scroll | Plug Fan | Plate |